Uf b wire s formal name refers to its uses.
Uf b wire ampacity.
The number and type of electrical devices connected to a circuit determine the ampacity requirement of the conductor.
Uf b feeds from a distribution point in an existing building.
Access control cable view pdf.
Low energy circuit cable type uf single conductor view pdf.
The cable can also be used as direct burial cable.
Jacket thickness for all nm b cable is 30 mils color code for 2 2 conductor cable is black white red and white with red stripe.
Where the number of current carrying conductors in a raceway or cable exceeds 3 the allowable ampacities shall be reduced per the table below.
Uf b cable is typically used as an underground feeder cable to distribute power from an existing building to outdoor lighting fixtures pumps outbuildings and other outdoor equipment.
Uf b has a heat capacity of 90 c and is rated at 600 volt.
Ampacities per national electrical code section 310 15 and 334 80 2011 edition note.
Allowable ampacities of insulated conductors rated 0 2000 volts as excerpted from the 2002 national electrical code ampacities of not more than three current carrying conductors in raceway cable or earth.
Color code for 4 conductor cable is black white red and blue.
Copper uf b view pdf.
You must use the correct size wire for the current load requirement of the circuit to prevent the wire from overheating.
The corrected and adjusted ampacity.
Usually a general purpose house circuit is designed for 20.
The equipment temperature limitation default values as described in nec 110 14 c 1.
Nm b is permitted to be.
Or the cable type temperature limitation.
The app limits the final ampacity of the wire to the most conservative of.
Current is measured in amperes or amps.
Copper tffn tfn tewn view pdf.
Table 310 15 b 3 a adjustment factors for more than three current carrying conductors in a raceway or cable.
View the southwire company 100 ft.
What does ufb mean.
Copper rhh rhw 2 use 2 view pdf.
A 2 500 b 1 000 c 500 d 125 e 250 f 500.
It can also be used for outbuildings such as garages and barns.
Nec tables are based on table 310 15 b 16 formerly table 310 16 allowable ampacities of insulated conductors rated up to and including 2000 volts 60 c through 90 c not more than three current carrying conductors in raceway cable or earth directly buried based on ambient temperature of 30 c.
Set your store to see local availability add to cart.
Category 5e cable view pdf.
Underground feeder building wire assortment 112 69 1 13 ft 112 69 1 13 ft free delivery.
U nderground f eeder and b ranch circuit wiring cable applications.
The calculator will permit choosing nm b and uf b up to 2 awg.